Number of the records: 1
Using a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T
Title Using a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T Author Valkovič Ladislav 1986 SAVMER - Ústav merania SAV SCOPUS RID ORCID Co-authors Dragonu I. Almujayyaz S. Batzakis A. Young L.A.J. Purvis L.A.B. Clarke W.T. Wichmann T. Lanz T. Neubauer S. Robson M.D. Klomp D.W.J. Rodgers C.T. Source document PLoS ONE. Vol. 12, no. 10 (2017), art. no. e0187153 Language eng - English Document kind rozpis článkov z periodík (rbx) Citations DELLEGROTTAGLIE, Santo - SCATTEIA, Alessandra - PASCALE, Carmine Emanuele - RENGA, Francesco - PERRONE-FILARDI, Pasquale. Evaluation of Cardiac Metabolism by Magnetic Resonance Spectroscopy in Heart Failure. In HEART FAILURE CLINICS. ISSN 1551-7136, 2019, vol. 15, no. 3, pp. 421. LOTT, Johanna - PLATT, Tanja - NIESPOREK, Sebastian C. - PAECH, Daniel - BEHL, Nicolas G. R. - NIENDORF, Thoralf - BACHERT, Peter - LADD, Mark E. - NAGEL, Armin M. Corrections of myocardial tissue sodium concentration measurements in human cardiac Na-23 MRI at 7 Tesla. In MAGNETIC RESONANCE IN MEDICINE. ISSN 0740-3194, 2019, vol. 82, no. 1, pp. 159-173. KRAFF, Oliver - QUICK, Harald H. Radiofrequency Coils for 7 Tesla MRI. In TOPICS IN MAGNETIC RESONANCE IMAGING. ISSN 0899-3459, 2019, vol. 28, no. 3, pp. 145-158. NIESPOREK, Sebastian C. - NAGEL, Armin M. - PLATT, Tanja. Multinuclear MRI at Ultrahigh Fields. In TOPICS IN MAGNETIC RESONANCE IMAGING. ISSN 0899-3459, 2019, vol. 28, no. 3, pp. 173-188. ROAT, S. - VIT, M. - WAMPL, S. - SCHMID, A.I. - LAISTLER, E. A Flexible Array for Cardiac P-31 MR Spectroscopy at 7 T. In FRONTIERS IN PHYSICS. ISSN 2296-424X, 2020, vol. 8. AHMAD, S.F. - KIM, Y.C. - CHOI, I.C. - KIM, H.D. Recent Progress in Birdcage RF Coil Technology for MRI System. In DIAGNOSTICS, 2020, vol. 10, no. 12. RIVERA, D. - KALLEVEEN, I. - DE CASTRO, C.A. - VAN LAARHOVEN, H. - KLOM, D. - VAN DER KEMP, W. - STOKER, J. - NEDERVEEN, A. Inherently decoupled H-1 antennas and P-31 loops for metabolic imaging of liver metastasis at 7 T. In NMR IN BIOMEDICINE. ISSN 0952-3480, 2020, vol. 33, no. 4. WILCOX, M. - WRIGHT, S.M. - MCDOUGALL, M. A Review of Non-H-1 RF Receive Arrays in Magnetic Resonance Imaging and Spectroscopy. In IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY, 2020, vol. 1, p. 290-300. REITER, T. - LOHR, D. - HOCK, M. - ANKENBRAND, M.J. - STEFANESCU, M.R. - KOSMALA, A. - KASPAR, M. - JUCHEM, C. - TEREKHOV, M. - SCHREIBER, L.M. On the way to routine cardiac MRI at 7 Tesla-a pilot study on consecutive 84 examinations. In PLOS ONE. ISSN 1932-6203, 2021, vol. 16, no. 7. Dostupné na: https://doi.org/10.1371/journal.pone.0252797. WILCOX, M. - OGIER, S. - CHESHKOV, S. - DIMITROV, I. - MALLOY, C. - WRIGHT, S. - MCDOUGALL, M. A 16-Channel 13C Array Coil for Magnetic Resonance Spectroscopy of the Breast at 7T. In IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING. ISSN 0018-9294, 2021, vol. 68, no. 6, p. 2036-2046. Dostupné na: https://doi.org/10.1109/TBME.2021.3063061. PLATT, T. - LADD, M.E. - PAECH, D. 7 Tesla and Beyond Advanced Methods and Clinical Applications in Magnetic Resonance Imaging. In INVESTIGATIVE RADIOLOGY. ISSN 0020-9996, NOV 2021, vol. 56, no. 11, p. 705-725. Dostupné na: https://doi.org/10.1097/RLI.0000000000000820. FAGAN, A.J. - BITZ, A.K. - BJORKMAN-BURTSCHER, I.M. - COLLINS, C.M. - KIMBRELL, V. - RAAIJMAKERS, A.J.E. 7T MRSafety. In JOURNAL OF MAGNETIC RESONANCE IMAGING. ISSN 1053-1807, FEB 2021, vol. 53, no. 2, p. 333-346. Dostupné na: https://doi.org/10.1002/jmri.27319. ZHU, Y. - SAPPO, C.R. - GRISSOM, W.A. - GORE, J.C. - YAN, X.Q. Dual-Tuned Lattice Balun for Multi-Nuclear MRI and MRS. In IEEE TRANSACTIONS ON MEDICAL IMAGING. ISSN 0278-0062, JUN 2022, vol. 41, no. 6, p. 1420-1430. Dostupné na: https://doi.org/10.1109/TMI.2022.3140717. CHOI, C.H. - HONG, S.M. - FELDER, J. - TELLMANN, L. - SCHEINS, J. - KOPS, E.R. - LERCHE, C. - SHAH, N.J. A Novel J-Shape Antenna Array for Simultaneous MR-PET or MR-SPECT Imaging. In IEEE TRANSACTIONS ON MEDICAL IMAGING. ISSN 0278-0062, MAY 2022, vol. 41, no. 5, p. 1104-1113. Dostupné na: https://doi.org/10.1109/TMI.2021.3132576. RIVERA, D. Emerging Role for 7T MRI and Metabolic Imaging for Pancreatic and Liver Cancer. In METABOLITES. MAY 2022, vol. 12, no. 5. Dostupné na: https://doi.org/10.3390/metabo12050409. SEO, J.H. - CHUNG, J.Y. A Preliminary Study for Reference RF Coil at 11.7 T MRI: Based on Electromagnetic Field Simulation of Hybrid-BC RF Coil According to Diameter and Length at 3.0, 7.0 and 11.7 T. In SENSORS. FEB 2022, vol. 22, no. 4. Dostupné na: https://doi.org/10.3390/s22041512. PARASOGLOU, P. - OSORIO, R.S. - KHEGAI, O. - KOVBASYUK, Z. - MILLER, M. - HO, A. - DEHKHARGHANI, S. - WISNIEWSKI, T. - CONVIT, A. - MOSCONI, L. - BROWN, R. Phosphorus metabolism in the brain of cognitively normal midlife individuals at risk for Alzheimer's disease. In NEUROIMAGE: REPORTS, 2022, vol. 2, no. 4. Dostupné na: https://doi.org/10.1016/j.ynirp.2022.100121. GUPTA, A. Cardiac SUP31/SUPP MR spectroscopy: development of the past five decades and future vision-will it be of diagnostic use in clinics?. In HEART FAILURE REVIEWS. ISSN 1382-4147, 2023 MAR 2023, vol. 28, no. 2, SI, p. 485-532. Dostupné na: https://doi.org/10.1007/s10741-022-10287-x. VAN DEN WILDENBERG, L. - GURSAN, A. - SEELEN, L.W.F. - VAN DER VELDEN, T.A. - GOSSELINK, M.W.J.M. - FROELING, M. - VAN DER KEMP, W.J.M. - KLOMP, D.W.J. - PROMPERS, J.J. In vivo phosphorus magnetic resonance spectroscopic imaging of the whole human liver at 7 T using a phosphorus whole-body transmit coil and 16-channel receive array: Repeatability and effects of principal component analysis-based denoising. In NMR IN BIOMEDICINE. ISSN 0952-3480, 2023 MAY 2023, vol. 36, no. 5. Dostupné na: https://doi.org/10.1002/nbm.4877. Category ADMA - Scientific papers in foreign impacted journals registered in Web of Sciences or Scopus Category of document (from 2022) V3 - Vedecký výstup publikačnej činnosti z časopisu Type of document článok Year 2017 Registered in WOS Registered in SCOPUS DOI 10.1371/journal.pone.0187153 article
File name Access Size Downloaded Type License Using a whole-body 31P birdcage transmit coil and 16-element.pdf available 3.6 MB 2 Publisher's version rok CC IF IF Q (best) JCR Av Jour IF Perc SJR SJR Q (best) CiteScore N rok vydania rok metriky IF IF Q (best) SJR SJR Q (best) 2017 2016 2.806 Q1 1.236 Q1
Number of the records: 1