Počet záznamov: 1  

Charring layer on a cross-laminated timber panel construction

  1. NázovCharring layer on a cross-laminated timber panel construction
    Aut.údajeKatarína Dúbravská ... [et al.]
    Autor Dúbravská Katarína TUZDFPO - Katedra protipožiarnej ochrany
    Spoluautori Špilák Dominik TUZDFPO - Katedra protipožiarnej ochrany
    Tereňová Ľudmila TUZDFPO - Katedra protipožiarnej ochrany
    Štefková Jaroslava TUZJA - Ústav cudzích jazykov
    Zdroj.dok. Acta Facultatis Xylologiae Zvolen : vedecký časopis Drevárskej fakulty. Vol. 61, no. 2 (2019), s. 109-119. - Zvolen : Technická univerzita vo Zvolene, 2019
    PoznámkyLit.
    Jazyk dok.angličtina
    KrajinaSlovenská republika
    Systematika630*827
    630*82
    681.3.06
    004.42
    Heslá lamelové drevo - laminated wood * lepené dyhové drevo - laminated veneer lumber * zuhoľnatené vrstvy - carbonized layers * zuhoľňovanie dreva - wood charring rate * programové systémy - program systems * ANSYS (počítačový systém) - ANSYS (computer system) Engineering Analysis System
    AnotáciaWhen the wood is thermally loaded, the microscopic changes of wood structure and macroscopic changes appear and are examined. The macroscopic changes include formation of char layeron the surface of the wood-based material.The main aim of the medium-scale test is to assess the char layer formation on the surface of the sample under thermal loading. The test sample was made of CLT (cross-laminated timber) panel with no surface treatment with the dimensions of 1000 ×1500 ×80 mm. It was a 3-layer panel made of spruce lamellas.The test sample underwent a medium-scaletest during which it was exposed to a radiation panel for 40 minutes. Intensity of the radiation panel was 43.1 kW·m-2. During the test,the temperature on the exposed side of the test sample was recorded by a thermocouple. The test sample immediately began to degrade and char. After complete charring of the CLT panel layer on the exposed side, its rupture and consequent falling off appeared. The middle layer of the CLT panel was minimal, only in the area where the outer layer fell off.The results of the medium-scale test were compared to the results of the simulation which were achieved from the Ansys 18.1 program. When the medium-scale test and simulation results were compared, some differences were found. The main difference was found when the char layer fell off from the CLT panel and further charring into the depth of the sample followed in the medium-scale test.
    URLhttps://df.tuzvo.sk/sites/default/files/11-02-19_1.pdf
    Kategória publikačnej činnosti ADN
    Báza dátxcla - ČLÁNKY
    Druh dok.RBX - rozpis článkov z periodík
    OdkazyPERIODIKÁ-Súborný záznam periodika
    Zväzky2019: 1-2
    článok

    článok

Počet záznamov: 1  

  Tieto stránky využívajú súbory cookies, ktoré uľahčujú ich prezeranie. Ďalšie informácie o tom ako používame cookies.